Unable to compare with previous version: Unable to find version history at https://gematik.de/fhir/isik/ (Problem #1 with package-list.json at https://gematik.de/fhir/isik/: Not Found)
IPA Comparison:
n/a
IPS Comparison:
n/a
Validation Flags:
On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
This IG is version 4.0.1, while the IG 'hl7.fhir.uv.subscriptions-backport.r4' is from version 4.0.0
ImplementationGuide.dependency[5].url
warning
The canonical URL for an Implementation Guide must point directly to the implementation guide resource, not to the Implementation Guide as a whole
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Procedure/Appendektomie. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Patient/DorisQuelle. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Patient/DorisZiel. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleISiKLaboruntersuchungMaximal. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleISiKLaboruntersuchungSerumnatrium1. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganPupilLightReactionLeft20200311. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganPupilLightReactionLeftPrompt20200311. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganPupilLightReactionLeftVerzogert20200311. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganPupilLightReactionRight20200311. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganPupilLightReactionRightKeine20200311. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganRASS20200311. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganSerumNatrium202003110104. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganSerumNatrium202003110159. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganSerumNatrium202003110306. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationMode20200311. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModeASV. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModeBiLev. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModeNIV. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModePCMod. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModePSIMV. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModeSPNMod. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModeStMod. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModenC. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/Fachabteilungskontakt. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktBettenverlegung. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktEntlassung. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktFachbereichswechsel1. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktFachbereichswechsel2. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktMinimal2. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktNormal. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktStationaereAufnahme. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktStationswechsel1. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktStationswechsel2. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ISiKGCSExample. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ISiKGCSMaxExample. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ISiKGCSMinExample. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Location/isik-station-anaesthesie. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/Intrakranieller-Druck-ICP. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Patient/IsikPatientTemplate. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Location/KrankenhausStandortBeispiel. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Patient/PatientinMinimal. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Patient/PatientinMusterfrau. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Patient/PatientinNormal. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Procedure/ReanimationBeispiel. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/SZ1Nachstationaer. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Patient/SZ1Patient. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/SZ1Stationaer. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/SZ1Vorstationaer. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/SZ2Encounter. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Patient/SZ2Patient. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Location/StationICUStandortBeispiel. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Location/StationPediaICUStandortBeispiel. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Location/StationStandortBeispiel. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Encounter/isik-encounter-Sternenfall. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Patient/isik-patient-156722. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
output/Akteure.html
information
The html source does not contain the publish box; this is recommended for publishing support (see note at https://confluence.hl7.org/spaces/FHIR/pages/66930646/FHIR+Implementation+Guide+Publishing+Requirements#FHIRImplementationGuidePublishingRequirements-PublishBox). Note that this is mandatory for HL7 specifications, and on the ci-build, but in other cases it's still recommended (this is only reported once, but applies for all pages)
The link 'https://gematik.de/fhir/isik/StructureDefinition/ExtensionISiKCapabilityStatementImportsExpectation' for "CapabilityStatement-Imports-Expectation-Extension" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ExtensionISiKCapabilityStatementImportsExpectation' for "CapabilityStatement-Imports-Expectation-Extension" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/CapabilityStatement/ISiKCapabilityStatementStammdatenRolle' for "CapabilityStatement zur Stammdaten-Abfrage" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
No conformance term found in the text: 301 Abs. 3 SGB V. Dieser gehört zu den ‘Medizinischen Daten des Behandlungsfalls’ entsprechend der Definitionen für die Datenübermittlung
nach CONFORMANCE_STATEMENT_NOCONFWORD
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
The link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versionsHTML_LINK_VERSIONLESS_CANONICAL
1
warning
The HTML fragment 'ip-statements.xhtml' is not included anywhere in the produced implementation guide
2
warning
An HTML fragment from the set [cross-version-analysis.xhtml, cross-version-analysis-inline.xhtml] is not included anywhere in the produced implementation guide
3
warning
An HTML fragment from the set [dependency-table.xhtml, dependency-table-short.xhtml, dependency-table-nontech.xhtml] is not included anywhere in the produced implementation guide
4
warning
The HTML fragment 'globals-table.xhtml' is not included anywhere in the produced implementation guide
Conformance resource /__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/fsh-generated/resources/ImplementationGuide-Organspendeerkennung.json - the canonical URL (https://gematik.de/fhir/isik/ImplementationGuide/Organspendeerkennung) does not match the URL (https://gematik.de/fhir/isik//ImplementationGuide/Organspendeerkennung). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
A definition could not be found for Canonical URL 'http://fhir.org/packages/de.basisprofil.r4/ImplementationGuide/de.basisprofil.r4'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE
A definition could not be found for Canonical URL 'http://fhir.org/packages/dvmd.kdl.r4/ImplementationGuide/dvmd.kdl.r4'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE
value should not start or finish with whitespace '\nDieses Profil ermöglicht die Abbildung von Besuchen/Aufenthalten eines Patienten in einer Gesundheitseinrichtung.\n\n**Motivation**\n\nInformationen über die Besuche des Patienten entlang seines \nBehandlungspfades im Krankenhaus sind ein wichtiger Bestandteil \ndes einrichtungsinternen Datenaustausches. \nSie ermöglichen die Unterscheidung von stationären und ambulanten \nsowie aufgenommenen und entlassenen Patienten. \nWeiterhin ist aus den Besuchsinformationen der aktuelle Aufenthaltsort \ndes Patienten (Fachabteilung, Station, Bettplatz) ermittelbar. \nKlinische Ressourcen werden in FHIR durch Verlinkung auf die \nEncounter-Ressource in einen Kontext zum Besuch gestellt. \nDieser Kontext ist wichtig für die Steuerung von Zugriffsberechtigungen \nund Abrechnungsprozessen. \n\nZu Beginn der meisten klinischen Workflows steht die Auswahl \ndes Besuchskontextes. \nDies geschieht bspw. durch das Suchen der Encounter-Ressource \nanhand von Eigenschaften wie Aufnahmenummer, Fallart oder Aufnahmedatum. \nDaraufhin werden die zutreffenden Suchergebnisse angezeigt \nund der gewünschte Besuch ausgewählt.\n\nIn FHIR werden Besuche, Aufenthalte, aber auch virtuelle Kontakte mit der `Encounter`-Ressource repräsentiert.\n\nWeitere Hinweise zu den Abgrenzungen der Begrifflichkeiten Fall und Kontakt finden sie unter [Fall-Begriff in ISiK](https://gemspec.gematik.de/ig/fhir/isik/basis/6.0.0-rc/Abbildung-des-Konstrukts-Fall.html).\n\n**Kompatibilität**\n\nFür das Profil ISiKKontaktGesundheitseinrichtung wird eine Kompatibilität \nmit folgenden Profilen angestrebt; \nallerdings kann nicht sichergestellt werden, dass Instanzen, \ndie gegen ISiKKontaktGesundheitseinrichtung valide sind, \nauch valide sind gegen:\n\n* Profil [Kontakt mit einer Gesundheitseinrichtung \nder Medizininformatik-Initiative](https://www.medizininformatik-initiative.de/fhir/core/modul-fall/StructureDefinition/KontaktGesundheitseinrichtung)\n\nHinweise zu Inkompatibilitäten können über die [Portalseite](https://service.gematik.de/servicedesk/customer/portal/16) gemeldet werden.'Type_Specific_Checks_DT_String_WS
value should not start or finish with whitespace ' Zulaessige Koerperstellen fuer lateralisierte Pupillenbefunde: linke oder rechte Pupille.\n\nDie Datenstruktur wurde dem laufenden Stand der Entwicklung des MII ICU Module entnommen - https://github.com/medizininformatik-initiative/kerndatensatzmodul-intensivmedizin/blob/master/input/fsh/valuesets/MII_VS_ICU_BodySite_Observation_Pupillenbefund.fsh - Details zur Kompatibilität mit dem ISiK Package der Stufe 6 wurden angepasst und Metadaten des Ursprungsschemas zum Teil entfernt. Stand 04.03.2026'Type_Specific_Checks_DT_String_WS
The ImplementationGuide uses package hl7.fhir.uv.ips#1.1.0 released on 2022-11-22, but the most recent appropriate version is 2.0.0. This reference is getting old and the more recent version should be consideredIG_DEPENDENCY_VERSION_WARNING_OLD
--
ImplementationGuide.dependsOn[3] (l1/c2315)
warning
The ImplementationGuide is based on FHIR version 4.0.1 but package hl7.fhir.uv.subscriptions-backport.r4#1.1.0 is based on FHIR version 4.0.0. In general, this version mismatch should be avoided - some tools will try to make this work with variable degrees of success, but others will not even tryIG_DEPENDENCY_VERSION_WARNING
--
ImplementationGuide.dependsOn[4] (l1/c2481)
warning
The canonical URL http://fhir.org/packages/de.basisprofil.r4/ImplementationGuide/de.basisprofil.r4 doesn't point to an actual ImplementationGuide resourceIG_DEPENDENCY_INVALID_URL
--
ImplementationGuide.dependsOn[5] (l1/c2617)
error
The URL should refer directly to the ImplementationGuide resource (e.g. include '/ImplementationGuide/')IG_DEPENDENCY_DIRECT
--
ImplementationGuide.dependsOn[5] (l1/c2617)
warning
The canonical URL http://fhir.de/packages/de.ihe-d.terminology doesn't point to an actual ImplementationGuide resourceIG_DEPENDENCY_INVALID_URL
--
ImplementationGuide.dependsOn[6] (l1/c2762)
warning
The canonical URL http://fhir.org/packages/dvmd.kdl.r4/ImplementationGuide/dvmd.kdl.r4 doesn't point to an actual ImplementationGuide resourceIG_DEPENDENCY_INVALID_URL
--
ImplementationGuide.dependsOn[7] (l1/c2941)
warning
The ImplementationGuide uses package ihe.formatcode.fhir#1.4.0 released on 2025-05-20, but the most recent appropriate version is 1.5.0. This reference is getting old and the more recent version should be consideredIG_DEPENDENCY_VERSION_WARNING_OLD
--
ImplementationGuide.dependsOn[8] (l1/c3085)
warning
The ImplementationGuide uses package hl7.fhir.uv.sdc#3.0.0 released on 2022-03-08, but the most recent appropriate version is 4.0.0. This reference is getting old and the more recent version should be consideredIG_DEPENDENCY_VERSION_WARNING_OLD
A definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/ImplementationGuide/ISiK-Basismodul'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE
URL Mismatch https://gematik.de/fhir/isik//CapabilityStatement/ISiKCapabilityStatementErweiterteStammdatenRolle vs https://gematik.de/fhir/isik/CapabilityStatement/ISiKCapabilityStatementErweiterteStammdatenRolle
URL Mismatch https://gematik.de/fhir/isik//CapabilityStatement/ISiKCapabilityStatementOrganspendeerkennungSourceAkteur vs https://gematik.de/fhir/isik/CapabilityStatement/ISiKCapabilityStatementOrganspendeerkennungSourceAkteur
URL Mismatch https://gematik.de/fhir/isik//CapabilityStatement/ISiKCapabilityStatementOrganspendeerkennungSourceAkteur-expanded vs https://gematik.de/fhir/isik/CapabilityStatement/ISiKCapabilityStatementOrganspendeerkennungSourceAkteur-expanded
URL Mismatch https://gematik.de/fhir/isik//CapabilityStatement/ISiKCapabilityStatementOrganspendeerkennungSourceRolle vs https://gematik.de/fhir/isik/CapabilityStatement/ISiKCapabilityStatementOrganspendeerkennungSourceRolle
A definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/ImplementationGuide/ISiK-Basismodul'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE
URL Mismatch https://gematik.de/fhir/isik//CapabilityStatement/ISiKCapabilityStatementStammdatenRolle vs https://gematik.de/fhir/isik/CapabilityStatement/ISiKCapabilityStatementStammdatenRolle
Published code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING
URL Mismatch https://gematik.de/fhir/isik//CodeSystem/ISiKBehandlungsergebnisRehaCS vs https://gematik.de/fhir/isik/CodeSystem/ISiKBehandlungsergebnisRehaCS
Published code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING
URL Mismatch https://gematik.de/fhir/isik//CodeSystem/ISiKBesondereBehandlungsformRehaCS vs https://gematik.de/fhir/isik/CodeSystem/ISiKBesondereBehandlungsformRehaCS
URL Mismatch https://gematik.de/fhir/isik//CodeSystem/ISiKEncounterTypeErweiterungCS vs https://gematik.de/fhir/isik/CodeSystem/ISiKEncounterTypeErweiterungCS
Published code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING
Published code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')Terminology_TX_NoValid_12
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
Encounter.location[2]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'ro')).exists() and status.where(value = 'active').exists()
,
Encounter.location[2]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'bd')).exists() and status.where(value = 'active').exists()
,
Encounter.location[2]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'wa')).exists() and status.where(value = 'active').exists()
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')Terminology_TX_NoValid_12
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')Terminology_TX_NoValid_12
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
Encounter.location[2]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'ro')).exists() and status.where(value = 'active').exists()
,
Encounter.location[2]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'bd')).exists() and status.where(value = 'active').exists()
,
Encounter.location[2]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'wa')).exists() and status.where(value = 'active').exists()
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')Terminology_TX_NoValid_12
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')Terminology_TX_NoValid_12
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')Terminology_TX_NoValid_12
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
Encounter.location[2]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'ro')).exists() and status.where(value = 'active').exists()
,
Encounter.location[2]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'bd')).exists() and status.where(value = 'active').exists()
,
Encounter.location[2]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'wa')).exists() and status.where(value = 'active').exists()
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
Encounter.location[3]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'ro')).exists() and status.where(value = 'active').exists()
,
Encounter.location[3]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'bd')).exists() and status.where(value = 'active').exists()
,
Encounter.location[3]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'wa')).exists() and status.where(value = 'active').exists()
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')Terminology_TX_NoValid_12
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')Terminology_TX_NoValid_12
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')Terminology_TX_NoValid_12
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')Terminology_TX_NoValid_12
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#AMB) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#AMB' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')Terminology_TX_NoValid_12
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')Terminology_TX_NoValid_12
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#AMB) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#AMB' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')Terminology_TX_NoValid_12
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')Terminology_TX_NoValid_12
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
Encounter.location[0]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'ro')).exists() and status.where(value = 'active').exists()
,
Encounter.location[0]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'bd')).exists() and status.where(value = 'active').exists()
,
Encounter.location[0]: discriminator = true and physicalType.coding.where((system = 'http://terminology.hl7.org/CodeSystem/location-physical-type') and (code = 'wa')).exists() and status.where(value = 'active').exists()
Wrong Display Name 'Inpatient' for http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP. Valid display is 'inpatient encounter' (en) (for the language(s) 'en-US')Display_Name_for__should_be_one_of__instead_of
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP: 'Inpatient'' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc'; Wrong Display Name 'Inpatient' for http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP. Valid display is 'inpatient encounter' (en) (for the language(s) 'en-US'))Terminology_TX_NoValid_12
Wrong Display Name 'belegt' for http://terminology.hl7.org/CodeSystem/v2-0116#O. Valid display is 'Occupied' (en) (for the language(s) 'en-US')Display_Name_for__should_be_one_of__instead_of
Wrong Display Name 'belegt' for http://terminology.hl7.org/CodeSystem/v2-0116#O. Valid display is 'Occupied' (en) (for the language(s) 'en-US')Display_Name_for__should_be_one_of__instead_of
Wrong Display Name 'belegt' for http://terminology.hl7.org/CodeSystem/v2-0116#O. Valid display is 'Occupied' (en) (for the language(s) 'en-US')Display_Name_for__should_be_one_of__instead_of
Wrong Display Name 'belegt' for http://terminology.hl7.org/CodeSystem/v2-0116#O. Valid display is 'Occupied' (en) (for the language(s) 'en-US')Display_Name_for__should_be_one_of__instead_of
Wrong Display Name 'belegt' for http://terminology.hl7.org/CodeSystem/v2-0116#O. Valid display is 'Occupied' (en) (for the language(s) 'en-US')Display_Name_for__should_be_one_of__instead_of
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKLaboruntersuchung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKLaboruntersuchung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
Observation.category[1]: discriminator = true and $this.coding.where((system = 'http://terminology.hl7.org/CodeSystem/observation-category') and (code = 'laboratory')).exists()
,
Observation.category[1]: discriminator = true and ($this memberOf 'https://gematik.de/fhir/isik/ValueSet/ISiKLaborbereichVS')
Wrong Display Name 'Serologie' for http://loinc.org#18727-8. Valid display is one of 2 choices: 'Serology studies (set)' (en-US) or 'Serology studies (set)' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
Wrong Display Name 'Methicillin-resistenter Staphylococcus aureus [Nachweis] in Probenmaterial mittels erregerspezifischer Kultur' for http://loinc.org#13317-3. Valid display is one of 3 choices: 'Methicillin resistant Staphylococcus aureus [Presence] in Specimen by Organism specific culture' (en-US), 'Methicillin resistant Staphylococcus aureus [Presence] in Specimen by Organism specific culture' (en-US) or 'MRSA Spec Ql Cult' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#13317-3 ("Methicillin-resistenter Staphylococcus aureus [Nachweis] in Probenmaterial mittels erregerspezifischer Kultur")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#13317-3"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "13317-3" found in http://loinc.org|2.82
Wrong Display Name 'Positiv' for http://snomed.info/sct#10828004. Valid display is one of 6 choices: 'Positive' (en), 'Positive for' (en), 'Ruled in' (en), 'Presence of' (en), 'Present' (en) or 'Positive (qualifier value)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
Unknown code '726446007' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/900000000000207008/version/20250201' (International Edition) (from https://tx.fhir.org/r4, see log, or see the servers logic) Unknown_Code_in_Version
0ms tx-op
0ms https://gematik.de/fhir/isik/ValueSet/ISiKLaborMethodeVS|6.0.0-rc: Analysing https://gematik.de/fhir/isik/ValueSet/ISiKLaborMethodeVS|6.0.0-rc for validation purposes
0ms https://gematik.de/fhir/isik/ValueSet/ISiKLaborMethodeVS|6.0.0-rc: Parameters: disp-lang=en-US, generate-narrative, default-to-latest
0ms https://gematik.de/fhir/isik/ValueSet/ISiKLaborMethodeVS|6.0.0-rc: Prepare include[0]: "(http://snomed.info/sct)(conceptdescendent-of272394005)"
0ms https://gematik.de/fhir/isik/ValueSet/ISiKLaborMethodeVS|6.0.0-rc: CodeSystem found: "http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201"
0ms https://gematik.de/fhir/isik/ValueSet/ISiKLaborMethodeVS|6.0.0-rc: Validate "[http://snomed.info/sct#726446007 ("Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry technique")]"
0ms https://gematik.de/fhir/isik/ValueSet/ISiKLaborMethodeVS|6.0.0-rc: Check "http://snomed.info/sct#726446007"
0ms https://gematik.de/fhir/isik/ValueSet/ISiKLaborMethodeVS|6.0.0-rc: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct
0ms https://gematik.de/fhir/isik/ValueSet/ISiKLaborMethodeVS|6.0.0-rc: check code in (http://snomed.info/sct)(conceptdescendent-of272394005) at CodeableConcept.coding[0]
0ms https://gematik.de/fhir/isik/ValueSet/ISiKLaborMethodeVS|6.0.0-rc: Filter concept descendent-of 272394005: Code "726446007" not found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Weiblich' for http://snomed.info/sct#248152002. Valid display is one of 2 choices: 'Female' (en) or 'Female (finding)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#248152002 ("Weiblich")]"
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#248152002"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "248152002" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
None of the codings provided are in the value set 'MII VS ICU Score RASS' (https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass|6.0.0-rc), and a coding from this value set is required) (codes = http://loinc.org#LA33966-5) (from server, see log, or see the servers logic) Terminology_TX_NoValid_1_CC
0ms tx-op
0ms https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass|6.0.0-rc: Analysing https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass|6.0.0-rc for validation purposes
0ms https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass|6.0.0-rc: Parameters: disp-lang=en-US, generate-narrative, default-to-latest
0ms https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass|6.0.0-rc: Prepare include[0]: "(http://loinc.org)(LA17287-6,LA33959-0,LA33960-8,LA16474-1,LA33962-4,LA33963-2,LA33964-0,LA33965-7,LA33966-5,LA33967-3)"
1ms https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass|6.0.0-rc: CodeSystem found: "http://loinc.org|2.82"
1ms https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass|6.0.0-rc: Validate "[http://loinc.org#LA33966-5 ("Deep sedation -4")]"
2ms https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass|6.0.0-rc: Check "http://loinc.org#LA33966-5"
2ms https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass|6.0.0-rc: CodeSystem found: http://loinc.org|2.82 for http://loinc.org
2ms https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass|6.0.0-rc: check code in (http://loinc.org)(LA17287-6,LA33959-0,LA33960-8,LA16474-1,LA33962-4,LA33963-2,LA33964-0,LA33965-7,LA33966-5,LA33967-3) at CodeableConcept.coding[0]
2ms https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass|6.0.0-rc: Code "LA33966-5" in concept list, but not found in http://loinc.org|2.82: undefined
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.36.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_DRAFT
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#9269-2 ("Glasgow coma score total"), http://snomed.info/sct#248241002 ("Glasgow coma score"), urn:iso:std:iso:11073:10101#153728 ("MDC_SCORE_GLAS_COMA")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#9269-2"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "9269-2" found in http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: Check "http://snomed.info/sct#248241002"
2ms http://loinc.org/vs|2.82: Check "urn:iso:std:iso:11073:10101#153728"
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.36.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_DRAFT
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#9269-2 ("Glasgow coma score total"), http://snomed.info/sct#248241002 ("Glasgow coma score"), urn:iso:std:iso:11073:10101#153728 ("MDC_SCORE_GLAS_COMA")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#9269-2"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "9269-2" found in http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: Check "http://snomed.info/sct#248241002"
2ms http://loinc.org/vs|2.82: Check "urn:iso:std:iso:11073:10101#153728"
Wrong Display Name 'Eye opening spontaneously' for http://loinc.org#LA6556-0. Valid display is 'Eyes open spontaneously' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#LA6556-0 ("Eye opening spontaneously")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#LA6556-0"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "LA6556-0" found in http://loinc.org|2.82
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.36.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_DRAFT
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#250844005 ("Intracranial pressure"), http://loinc.org#60956-0 ("Intracranial pressure (ICP)"), urn:iso:std:iso:11073:10101#153608 ("Intracranial pressure")]"
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#250844005"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "250844005" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://loinc.org#60956-0"
2ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "urn:iso:std:iso:11073:10101#153608"
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.36.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_DRAFT
0ms tx-op
0ms https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-iso11073|6.0.0-rc: Analysing https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-iso11073|6.0.0-rc for validation purposes
0ms https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-iso11073|6.0.0-rc: Parameters: disp-lang=en-US, generate-narrative, default-to-latest
0ms https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-iso11073|6.0.0-rc: Prepare include[0]: "(urn:iso:std:iso:11073:10101)(150017,150019,150018,150084,150045,150047,150046,150052,150276,149772,149760,152852,150428,149764,150368,150456,160300,160296,153608,150103,150107,150101,150105,150102,150106,150069,150065,150067,150071,150066,150070,188420,188496,188424,188436,188500,147842,188504,149514,150372,150380,188452,150324,188796,150392,150356,150408,150636)"
0ms https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-iso11073|6.0.0-rc: CodeSystem found: "urn:iso:std:iso:11073:10101|2024-12-05"
0ms https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-iso11073|6.0.0-rc: Validate "[urn:iso:std:iso:11073:10101#153608 ("Intracranial pressure")]"
0ms https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-iso11073|6.0.0-rc: Check "urn:iso:std:iso:11073:10101#153608"
1ms https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-iso11073|6.0.0-rc: CodeSystem found: urn:iso:std:iso:11073:10101|2024-12-05 for urn:iso:std:iso:11073:10101
1ms https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-iso11073|6.0.0-rc: check code in (urn:iso:std:iso:11073:10101)(150017,150019,150018,150084,150045,150047,150046,150052,150276,149772,149760,152852,150428,149764,150368,150456,160300,160296,153608,150103,150107,150101,150105,150102,150106,150069,150065,150067,150071,150066,150070,188420,188496,188424,188436,188500,147842,188504,149514,150372,150380,188452,150324,188796,150392,150356,150408,150636) at Coding
1ms https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-iso11073|6.0.0-rc: Code "153608" found in urn:iso:std:iso:11073:10101|2024-12-05
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractContext could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractContext'Type_Specific_Checks_DT_URL_Resolve
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
Constraint failed: kvid-1: 'Der unveränderliche Teil der KVID muss 10-stellig sein und mit einem Großbuchstaben anfangen (matches('^[A-Z][0-9]{9}$'))' (defined in http://fhir.de/StructureDefinition/identifier-kvid-10)http://fhir.de/StructureDefinition/identifier-kvid-10#kvid-1
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractContext could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractContext'Type_Specific_Checks_DT_URL_Resolve
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
This element does not match any known slice defined in the profile http://fhir.de/StructureDefinition/humanname-de-basis|1.5.4 (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile http://fhir.de/StructureDefinition/humanname-de-basis|1.5.4 (this may not be a problem, but you should check that it's not intended to match a slice)
Patient.name[0].family.extension[0]: discriminator = true and ('http://fhir.de/StructureDefinition/humanname-namenszusatz' in url)
,
Patient.name[0].family.extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/humanname-own-name' in url)
,
Patient.name[0].family.extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/humanname-own-prefix' in url)
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
Patient.name[0].family.extension[0]: discriminator = true and ('http://fhir.de/StructureDefinition/humanname-namenszusatz' in url)
,
Patient.name[0].family.extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/humanname-own-name' in url)
,
Patient.name[0].family.extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/humanname-own-prefix' in url)
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractContext could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractContext'Type_Specific_Checks_DT_URL_Resolve
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
Patient.gender.extension[0]: discriminator = true and ('http://fhir.de/StructureDefinition/gender-amtlich-de' in url)
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
Patient.birthDate.extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/data-absent-reason' in url)
This element does not match any known slice defined in the profile http://fhir.de/StructureDefinition/address-de-basis|1.5.4 (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile http://fhir.de/StructureDefinition/address-de-basis|1.5.4 (this may not be a problem, but you should check that it's not intended to match a slice)
Patient.address[0].extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct' in url)
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractContext could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractContext'Type_Specific_Checks_DT_URL_Resolve
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
This element does not match any known slice defined in the profile http://fhir.de/StructureDefinition/address-de-basis|1.5.4 (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile http://fhir.de/StructureDefinition/address-de-basis|1.5.4 (this may not be a problem, but you should check that it's not intended to match a slice)
Patient.address[0].line[0].extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName' in url)
,
Patient.address[0].line[0].extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber' in url)
,
Patient.address[0].line[0].extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator' in url)
,
Patient.address[0].line[0].extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox' in url)
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
The extension http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue could not be found so is not allowed hereExtension_EXT_Unknown_NotHere
No definition could be found for URL value 'http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-templateExtractValue'Type_Specific_Checks_DT_URL_Resolve
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
Patient.address[0].extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct' in url)
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
Patient.address[0].line[0].extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName' in url)
,
Patient.address[0].line[0].extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber' in url)
,
Patient.address[0].line[0].extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator' in url)
,
Patient.address[0].line[0].extension[0]: discriminator = true and ('http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox' in url)
Wrong Display Name 'Chirurgische Prozedur' for http://snomed.info/sct#387713003. Valid display is one of 6 choices: 'Surgical procedure (procedure)' (en), 'Surgical procedure' (en), 'Operation' (en), 'Surgical procedures' (en), 'Operative procedure' (en) or 'Surgery' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#387713003 ("Chirurgische Prozedur")]"
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#387713003"
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "387713003" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Chirurgische Prozedur' for http://snomed.info/sct#387713003. Valid display is 'Surgical procedure (procedure)' (en), 'Surgical procedure' (en), 'Operation' (en), 'Surgical procedures' (en), 'Operative procedure' (en), 'Surgery' (en) or 'Surgical procedure' (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenKategorieSCT|6.0.0-rc: Analysing https://gematik.de/fhir/isik/ValueSet/ProzedurenKategorieSCT|6.0.0-rc for validation purposes
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenKategorieSCT|6.0.0-rc: Parameters: disp-lang=en-US, generate-narrative, default-to-latest
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenKategorieSCT|6.0.0-rc: Prepare include[0]: "(http://snomed.info/sct)(165197003,363679005,387713003,18629005,277132007,394841004)"
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenKategorieSCT|6.0.0-rc: CodeSystem found: "http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201"
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenKategorieSCT|6.0.0-rc: Validate "[http://snomed.info/sct#387713003 ("Chirurgische Prozedur")]"
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenKategorieSCT|6.0.0-rc: Check "http://snomed.info/sct#387713003"
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenKategorieSCT|6.0.0-rc: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenKategorieSCT|6.0.0-rc: check code in (http://snomed.info/sct)(165197003,363679005,387713003,18629005,277132007,394841004) at Coding
1ms https://gematik.de/fhir/isik/ValueSet/ProzedurenKategorieSCT|6.0.0-rc: Code "387713003" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Appendektomie' for http://snomed.info/sct#80146002. Valid display is one of 9 choices: 'Appendectomy' (en), 'Appendectomy, NOS' (en), 'Excision of appendix, NOS' (en), 'Primary appendectomy' (en), 'Appendicectomy, NOS' (en), 'Excision of appendix' (en), 'Appendicectomy' (en), 'Appendectomy (procedure)' (en) or 'Excision of appendix (procedure)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#80146002 ("Appendektomie"), http://fhir.de/CodeSystem/bfarm/ops|2024#5-470 ("Appendektomie")]"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#80146002"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "80146002" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://fhir.de/CodeSystem/bfarm/ops|2024#5-470"
A definition for CodeSystem 'http://fhir.de/CodeSystem/bfarm/ops' version '2024' could not be found, so the code cannot be validated. No versions of this code system are known (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM_VERSION_NONE
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#80146002 ("Appendektomie"), http://fhir.de/CodeSystem/bfarm/ops|2024#5-470 ("Appendektomie")]"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#80146002"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "80146002" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://fhir.de/CodeSystem/bfarm/ops|2024#5-470"
The code provided (http://snomed.info/sct#80146002) was not found in the value set 'ProzedurenCodesSCT' (https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT|6.0.0-rc), and a code from this value set is required: Wrong Display Name 'Appendektomie' for http://snomed.info/sct#80146002. Valid display is one of 9 choices: 'Appendectomy' (en), 'Appendectomy, NOS' (en), 'Excision of appendix, NOS' (en), 'Primary appendectomy' (en), 'Appendicectomy, NOS' (en), 'Excision of appendix' (en), 'Appendicectomy' (en), 'Appendectomy (procedure)' (en) or 'Excision of appendix (procedure)' (en) (for the language(s) 'en-US') (from server, see log, or see the servers logic) Terminology_TX_Confirm_4a
0ms tx-op
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT|6.0.0-rc: Analysing https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT|6.0.0-rc for validation purposes
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT|6.0.0-rc: Parameters: disp-lang=en-US, generate-narrative, default-to-latest
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT|6.0.0-rc: Prepare include[0]: "(http://snomed.info/sct)(conceptdescendent-of71388002)"
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT|6.0.0-rc: CodeSystem found: "http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201"
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT|6.0.0-rc: Validate "[http://snomed.info/sct#80146002 ("Appendektomie")]"
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT|6.0.0-rc: Check "http://snomed.info/sct#80146002"
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT|6.0.0-rc: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct
0ms https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT|6.0.0-rc: check code in (http://snomed.info/sct)(conceptdescendent-of71388002) at Coding
1ms https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT|6.0.0-rc: Filter concept descendent-of 71388002: Code "80146002" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000274103/version/20251115' could not be found, so the code cannot be validated. Valid versions: http://snomed.info/sct/11000146104/version/20240930, http://snomed.info/sct/11000172109/version/20231115, http://snomed.info/sct/2011000195101/version/20230607, http://snomed.info/sct/32506021000036107/version/20230731, http://snomed.info/sct/45991000052106/version/20231130, http://snomed.info/sct/554471000005108/version/20250930, http://snomed.info/sct/731000124108/version/20230301, http://snomed.info/sct/731000124108/version/20240301, http://snomed.info/sct/731000124108/version/20250901, http://snomed.info/sct/827022005/version/20241216, http://snomed.info/sct/83821000000107/version/20230412, http://snomed.info/sct/900000000000207008/version/20240201, http://snomed.info/sct/900000000000207008/version/20250201 and http://snomed.info/xsct/900000000000207008/version/20250814 (from https://tx.fhir.org/r4, see log) UNKNOWN_CODESYSTEM_VERSION
Wrong Display Name 'Kardiopulmonale Reanimation' for http://snomed.info/sct#89666000. Valid display is 'Cardiopulmonary resuscitation' (en-x-sctlang-90000000-00005090-07) (for the language(s) 'en-US') (from https://tx.fhir.de/fhir, see log)
The code provided (http://snomed.info/sct#89666000) was not found in the value set 'ProzedurenReanimationCodesSCT' (https://gematik.de/fhir/isik/ValueSet/ProzedurenReanimationCodesSCT|6.0.0-rc), and a code from this value set is required: Wrong Display Name 'Kardiopulmonale Reanimation' for http://snomed.info/sct#89666000. Valid display is 'Cardiopulmonary resuscitation' (en-x-sctlang-90000000-00005090-07) (for the language(s) 'en-US') (from server, see log) Terminology_TX_Confirm_4a
The code provided (http://fhir.de/CodeSystem/bfarm/ops#8-771) was not found in the value set 'ProzedurenReanimationCodesOPS' (https://gematik.de/fhir/isik/ValueSet/ProzedurenReanimationCodesOPS|6.0.0-rc), and a code from this value set is required: Cannot invoke "String.length()" because "prefix" is null (from server, see log, or see the servers logic) Terminology_TX_Confirm_4a
Local Error: Cannot invoke "String.length()" because "prefix" is null. Server Error: Cannot invoke "String.length()" because "prefix" is null
Constraint failed: spd-0: 'Name should be usable as an identifier for the module by machine processing applications such as code generation (name.matches('[A-Z]([A-Za-z0-9_]){0,254}'))'http://hl7.org/fhir/StructureDefinition/SearchParameter#spd-0
URL Mismatch https://gematik.de/fhir/isik//SearchParameter/Location-characteristic vs https://gematik.de/fhir/isik/SearchParameter/Location-characteristic
There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/conformance-expectation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '2.0.0', found versions: 0.3.0 (from hl7.terminology.r4#5.0.0), 1.0.0 (from hl7.terminology.r4#6.3.0), 2.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/conformance-expectation' to 'http://terminology.hl7.org/ValueSet/conformance-expectation|2.0.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/conformance-expectation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '2.0.0', found versions: 0.3.0 (from hl7.terminology.r4#5.0.0), 1.0.0 (from hl7.terminology.r4#6.3.0), 2.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/conformance-expectation' to 'http://terminology.hl7.org/ValueSet/conformance-expectation|2.0.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/ExtensionISiKCapabilityStatementImportsExpectation vs https://gematik.de/fhir/isik/StructureDefinition/ExtensionISiKCapabilityStatementImportsExpectation
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/ExtensionISiKRehaEntlassung vs https://gematik.de/fhir/isik/StructureDefinition/ExtensionISiKRehaEntlassung
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.36.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_DRAFT
0ms tx-op
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Validate "[urn:iso:std:iso:11073:10101#153728 ("undefined")]"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Check "urn:iso:std:iso:11073:10101#153728"
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: CodeSystem found: urn:iso:std:iso:11073:10101|2024-12-05 for urn:iso:std:iso:11073:10101|2024-12-05
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: check code in (urn:iso:std:iso:11073:10101) at Coding
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Code "153728" found in urn:iso:std:iso:11073:10101|2024-12-05
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.36.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_DRAFT
0ms tx-op
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Validate "[urn:iso:std:iso:11073:10101#153728 ("undefined")]"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Check "urn:iso:std:iso:11073:10101#153728"
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: CodeSystem found: urn:iso:std:iso:11073:10101|2024-12-05 for urn:iso:std:iso:11073:10101|2024-12-05
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: check code in (urn:iso:std:iso:11073:10101) at Coding
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Code "153728" found in urn:iso:std:iso:11073:10101|2024-12-05
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
--
StructureDefinition.snapshot (l1/c360646)
warning
The slice 'IEEE11073' on path 'Observation.code.coding' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
input/resources/StructureDefinition-ISiKGCS
error
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/ISiKGCS vs https://gematik.de/fhir/isik/StructureDefinition/ISiKGCS
There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ActEncounterCode'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ActEncounterCode' to 'http://terminology.hl7.org/ValueSet/v3-ActEncounterCode|3.0.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ActPriority'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ActPriority' to 'http://terminology.hl7.org/ValueSet/v3-ActPriority|3.0.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v2-0092'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v2-0092' to 'http://terminology.hl7.org/ValueSet/v2-0092|3.0.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
ISiK-enc-8: The left side is inherently a collection, and so the expression 'coding.code != 'billing'' may fail or return false if there is more than one item in the content being evaluatedFHIRPATH_COLLECTION_STATUS_OPERATION_LEFT
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/ISiKKontaktGesundheitseinrichtung vs https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)SD_VALUE_TYPE_REPEAT_HINT
--
StructureDefinition.snapshot (l1/c432488)
warning
The slice 'laborbereich' on path 'Observation.category' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
StructureDefinition.snapshot (l1/c432488)
warning
The slice 'valueCodeableConcept' on path 'Observation.value[x]' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/ISiKLaboruntersuchung vs https://gematik.de/fhir/isik/StructureDefinition/ISiKLaboruntersuchung
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)SD_VALUE_TYPE_REPEAT_HINT
--
StructureDefinition.snapshot (l1/c261062)
warning
The slice 'laborbereich' on path 'Observation.category' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
StructureDefinition.snapshot (l1/c261062)
warning
The slice 'valueCodeableConcept' on path 'Observation.value[x]' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/ISiKLaboruntersuchungSerumnatrium vs https://gematik.de/fhir/isik/StructureDefinition/ISiKLaboruntersuchungSerumnatrium
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-name'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-name' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-name|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
The extension http://hl7.org/fhir/StructureDefinition/regex|5.2.0 is deprecated with the note: 'This was deprecated in favor of using a constraint on the element using FHIRPath, since constraints allow for the provision of a human readable message associated with the regex'MSG_DEPENDS_ON_DEPRECATED_NOTE
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier' to 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/name-part-qualifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/name-part-qualifier' to 'http://hl7.org/fhir/ValueSet/name-part-qualifier|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-name'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-name' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-name|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier' to 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/data-absent-reason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/data-absent-reason' to 'http://hl7.org/fhir/StructureDefinition/data-absent-reason|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/data-absent-reason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/data-absent-reason' to 'http://hl7.org/fhir/StructureDefinition/data-absent-reason|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)SD_VALUE_TYPE_REPEAT_HINT
--
StructureDefinition.snapshot (l1/c461932)
warning
The slice 'Versichertennummer_PKV' on path 'Patient.identifier' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
input/resources/StructureDefinition-ISiKPatient
error
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/ISiKPatient vs https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
ISiK Prozedur Beatmung.coding.Procedure.code.coding
warning
Unable to check if https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-code-procedure-beatmung-snomed is a proper subset of https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT - value set is too large to check
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/ISiKProzedurBeatmung vs https://gematik.de/fhir/isik/StructureDefinition/ISiKProzedurBeatmung
ISiK Prozedur Reanimation.coding.Procedure.code.coding
warning
Unable to check if https://gematik.de/fhir/isik/ValueSet/ProzedurenReanimationCodesSCT is a proper subset of https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT - value set is too large to check
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/ISiKProzedurReanimation vs https://gematik.de/fhir/isik/StructureDefinition/ISiKProzedurReanimation
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/ISiKSnomedCTCoding vs https://gematik.de/fhir/isik/StructureDefinition/ISiKSnomedCTCoding
There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v2-0116'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v2-0116' to 'http://terminology.hl7.org/ValueSet/v2-0116|3.0.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType' to 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType|3.0.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
Conformance resource /__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-PlannedEndDate.json - the canonical URL (https://gematik.de/fhir/isik/StructureDefinition/PlannedEndDate) does not match the URL (http://hl7.org/fhir/5.0/StructureDefinition/extension-Encounter.plannedEndDate). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
--
StructureDefinition (l1/c16986)
error
When HL7 is publishing a resource, the owning committee must be stated using the http://hl7.org/fhir/StructureDefinition/structuredefinition-wg extensionVALIDATION_HL7_WG_NEEDED
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/PlannedEndDate vs http://hl7.org/fhir/5.0/StructureDefinition/extension-Encounter.plannedEndDate
Conformance resource /__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-PlannedStartDate.json - the canonical URL (https://gematik.de/fhir/isik/StructureDefinition/PlannedStartDate) does not match the URL (http://hl7.org/fhir/5.0/StructureDefinition/extension-Encounter.plannedStartDate). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
--
StructureDefinition (l1/c17068)
error
When HL7 is publishing a resource, the owning committee must be stated using the http://hl7.org/fhir/StructureDefinition/structuredefinition-wg extensionVALIDATION_HL7_WG_NEEDED
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/PlannedStartDate vs http://hl7.org/fhir/5.0/StructureDefinition/extension-Encounter.plannedStartDate
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.36.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_DRAFT
0ms tx-op
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Validate "[urn:iso:std:iso:11073:10101#153604 ("undefined")]"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Check "urn:iso:std:iso:11073:10101#153604"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: CodeSystem found: urn:iso:std:iso:11073:10101|2024-12-05 for urn:iso:std:iso:11073:10101|2024-12-05
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: check code in (urn:iso:std:iso:11073:10101) at Coding
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Code "153604" found in urn:iso:std:iso:11073:10101|2024-12-05
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.36.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_DRAFT
0ms tx-op
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Validate "[urn:iso:std:iso:11073:10101#153604 ("undefined")]"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Check "urn:iso:std:iso:11073:10101#153604"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: CodeSystem found: urn:iso:std:iso:11073:10101|2024-12-05 for urn:iso:std:iso:11073:10101|2024-12-05
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: check code in (urn:iso:std:iso:11073:10101) at Coding
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Code "153604" found in urn:iso:std:iso:11073:10101|2024-12-05
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/mii-pr-icu-muv-zerebraler-perfusionsdruck vs https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-muv-zerebraler-perfusionsdruck
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/mii-pr-icu-score-rass vs https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-score-rass
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/mii-pr-icu-untersuchung-pupillenbefund vs https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-untersuchung-pupillenbefund
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/mii-pr-icu-untersuchung-pupillenform vs https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-untersuchung-pupillenform
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
--
StructureDefinition.snapshot (l1/c198825)
warning
The slice 'valueCodeableConcept' on path 'Observation.value[x]' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
StructureDefinition.snapshot (l1/c198825)
warning
The slice 'valueQuantity' on path 'Observation.value[x]' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/mii-pr-icu-untersuchung-pupillengroesse vs https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-untersuchung-pupillengroesse
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/mii-pr-icu-untersuchung-pupillenlichtreaktion-direkt vs https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-untersuchung-pupillenlichtreaktion-direkt
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/mii-pr-icu-untersuchung-pupillenlichtreaktion-indirekt vs https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-untersuchung-pupillenlichtreaktion-indirekt
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/mii-pr-icu-untersuchung-pupillensymmetrie vs https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-untersuchung-pupillensymmetrie
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.36.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_DRAFT
0ms tx-op
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Validate "[urn:iso:std:iso:11073:10101#152498 ("undefined")]"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Check "urn:iso:std:iso:11073:10101#152498"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: CodeSystem found: urn:iso:std:iso:11073:10101|2024-12-05 for urn:iso:std:iso:11073:10101|2024-12-05
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: check code in (urn:iso:std:iso:11073:10101) at Coding
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Code "152498" found in urn:iso:std:iso:11073:10101|2024-12-05
A definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.36.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_DRAFT
0ms tx-op
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Validate "[urn:iso:std:iso:11073:10101#152498 ("undefined")]"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Check "urn:iso:std:iso:11073:10101#152498"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: CodeSystem found: urn:iso:std:iso:11073:10101|2024-12-05 for urn:iso:std:iso:11073:10101|2024-12-05
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: check code in (urn:iso:std:iso:11073:10101) at Coding
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Code "152498" found in urn:iso:std:iso:11073:10101|2024-12-05
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
Unable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmungSD_ED_TYPE_PROFILE_UNKNOWN
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/mii-pr-icu-vent-spontane-atemfrequenz-beatmet vs https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-spontane-atemfrequenz-beatmet
A definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
Unable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmungSD_ED_TYPE_PROFILE_UNKNOWN
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/mii-pr-icu-vent-spontanes-atemzugvolumen vs https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-spontanes-atemzugvolumen
A definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
Unable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmungSD_ED_TYPE_PROFILE_UNKNOWN
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/mii-pr-icu-vent-unterstuezungsdruck-beatmung vs https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-unterstuezungsdruck-beatmung
Cannot check whether the target profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung on Observation.device is valid constraint on the base because it is not known
A definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE
A definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
Unable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmungSD_ED_TYPE_PROFILE_UNKNOWN
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
Unable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmungSD_ED_TYPE_PROFILE_UNKNOWN
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/mii-pr-vent-icu-parameter-von-beatmung vs https://gematik.de/fhir/isik/StructureDefinition/mii-pr-vent-icu-parameter-von-beatmung
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.36.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_DRAFT
0ms tx-op
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Validate "[urn:iso:std:iso:11073:10101#153608 ("undefined")]"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Check "urn:iso:std:iso:11073:10101#153608"
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: CodeSystem found: urn:iso:std:iso:11073:10101|2024-12-05 for urn:iso:std:iso:11073:10101|2024-12-05
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: check code in (urn:iso:std:iso:11073:10101) at Coding
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Code "153608" found in urn:iso:std:iso:11073:10101|2024-12-05
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.36.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_DRAFT
0ms tx-op
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Validate "[urn:iso:std:iso:11073:10101#153608 ("undefined")]"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Check "urn:iso:std:iso:11073:10101#153608"
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: CodeSystem found: urn:iso:std:iso:11073:10101|2024-12-05 for urn:iso:std:iso:11073:10101|2024-12-05
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: check code in (urn:iso:std:iso:11073:10101) at Coding
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Code "153608" found in urn:iso:std:iso:11073:10101|2024-12-05
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/sd-mii-icu-intrakranieller-druck-icp vs https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-intrakranieller-druck-icp
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
Error in constraint 'mii-icu-1' with expression 'value.exists().not() implies dataAbsentReason.exists()': Error evaluating FHIRPath expression: The name 'value' is not valid for any of the possible types: [http://hl7.org/fhir/StructureDefinition/CodeableConcept] (@char 1)ED_INVARIANT_EXPRESSION_ERROR
URL Mismatch https://gematik.de/fhir/isik//StructureDefinition/sd-mii-icu-monitoring-und-vitaldaten vs https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-monitoring-und-vitaldaten
URL Mismatch https://gematik.de/fhir/isik//ValueSet/ISiKBesondereBehandlungsformReha vs https://gematik.de/fhir/isik/ValueSet/ISiKBesondereBehandlungsformReha
Pinned the version of http://terminology.hl7.org/CodeSystem/v3-ActCode to 10.0.0 from choices of 10.0.0 (hl7.terminology.r4#7.1.0), 7.0.0 (hl7.terminology.r4#5.0.0), 9.0.0 (hl7.terminology.r4#6.3.0)PIN_VERSION
--
input/resources/ValueSet-ISiKEncounterClassDE
error
URL Mismatch https://gematik.de/fhir/isik//ValueSet/ISiKEncounterClassDE vs https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE
URL Mismatch https://gematik.de/fhir/isik//ValueSet/ISiKEncounterTypeErweiterungVS vs https://gematik.de/fhir/isik/ValueSet/ISiKEncounterTypeErweiterungVS
Wrong Display Name 'BLOOD BANK STUDIES' for http://loinc.org#18717-9. Valid display is one of 2 choices: 'Blood bank studies (set)' (en-US) or 'Blood bank studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'CELL MARKER STUDIES' for http://loinc.org#18718-7. Valid display is one of 2 choices: 'Cell marker studies (set)' (en-US) or 'Cell marker studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'CHEMISTRY STUDIES' for http://loinc.org#18719-5. Valid display is one of 2 choices: 'Chemistry studies (set)' (en-US) or 'Chemistry studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'COAGULATION STUDIES' for http://loinc.org#18720-3. Valid display is one of 2 choices: 'Coagulation studies (set)' (en-US) or 'Coagulation studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'THERAPEUTIC DRUG MONITORING STUDIES' for http://loinc.org#18721-1. Valid display is one of 2 choices: 'Therapeutic drug monitoring studies (set)' (en-US) or 'Therapeutic drug monitoring studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'FERTILITY STUDIES' for http://loinc.org#18722-9. Valid display is one of 2 choices: 'Fertility studies (set)' (en-US) or 'Fertility studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'HEMATOLOGY STUDIES' for http://loinc.org#18723-7. Valid display is one of 2 choices: 'Hematology studies (set)' (en-US) or 'Hematology studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'SEROLOGY STUDIES' for http://loinc.org#18727-8. Valid display is one of 2 choices: 'Serology studies (set)' (en-US) or 'Serology studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'TOXICOLOGY STUDIES' for http://loinc.org#18728-6. Valid display is one of 2 choices: 'Toxicology studies (set)' (en-US) or 'Toxicology studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'URINALYSIS STUDIES' for http://loinc.org#18729-4. Valid display is one of 2 choices: 'Urinalysis studies (set)' (en-US) or 'Urinalysis studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'BLOOD GAS STUDIES' for http://loinc.org#18767-4. Valid display is one of 2 choices: 'Blood gas studies (set)' (en-US) or 'Blood gas studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'CELL COUNTS+DIFFERENTIAL STUDIES' for http://loinc.org#18768-2. Valid display is one of 2 choices: 'Cell counts+Differential studies (set)' (en-US) or 'Cell counts+Differential studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'LABORATORY STUDIES' for http://loinc.org#26436-6. Valid display is one of 2 choices: 'Laboratory studies (set)' (en-US) or 'Laboratory studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'CHEMISTRY CHALLENGE STUDIES' for http://loinc.org#26437-4. Valid display is one of 2 choices: 'Chemistry challenge studies (set)' (en-US) or 'Chemistry challenge studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
--
input/resources/ValueSet-ISiKLaborbereichVS
error
URL Mismatch https://gematik.de/fhir/isik//ValueSet/ISiKLaborbereichVS vs https://gematik.de/fhir/isik/ValueSet/ISiKLaborbereichVS
Wrong Display Name 'millimol per liter' for http://unitsofmeasure.org#mmol/L. Valid display is one of 2 choices: 'mmol/L' (en) or '(millimole) / (liter)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
--
ValueSet (l1/c1290)
warning
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.title is mandatory, but it is not present
Wrong Display Name 'Administration of medicine' for http://snomed.info/sct#18629005. Valid display is one of 9 choices: 'Administration of medication' (en), 'Administration of medication, NOS' (en), 'Giving medication' (en), 'Administration of medication (procedure)' (en), 'Medication administration' (en), 'Medication administration treatments and procedures' (en), 'Medication treatment' (en), 'Administration of drug or medicament (procedure)' (en) or 'Administration of drug or medicament' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
--
ValueSet (l1/c2072)
warning
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.title is mandatory, but it is not present
--
input/resources/ValueSet-ProzedurenKategorieSCT
error
URL Mismatch https://gematik.de/fhir/isik//ValueSet/ProzedurenKategorieSCT vs https://gematik.de/fhir/isik/ValueSet/ProzedurenKategorieSCT
Resolved system http://fhir.de/CodeSystem/bfarm/ops, but the definition doesn't include any codes, so the code has not been validatedResolved system http://fhir.de/CodeSystem/bfarm/ops, but the definition doesn't include any codes, so the code has not been validated
The code '8-772' is not valid in the system http://fhir.de/CodeSystem/bfarm/ops (A definition for CodeSystem 'http://fhir.de/CodeSystem/bfarm/ops' could not be found, so the code cannot be validated)VALUESET_INCLUDE_INVALID_CONCEPT_CODE
A definition for CodeSystem 'http://fhir.de/CodeSystem/bfarm/ops' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log) UNKNOWN_CODESYSTEM
The code '8-779' is not valid in the system http://fhir.de/CodeSystem/bfarm/ops (A definition for CodeSystem 'http://fhir.de/CodeSystem/bfarm/ops' could not be found, so the code cannot be validated)VALUESET_INCLUDE_INVALID_CONCEPT_CODE
A definition for CodeSystem 'http://fhir.de/CodeSystem/bfarm/ops' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log) UNKNOWN_CODESYSTEM
--
ValueSet (l1/c1671)
warning
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.title is mandatory, but it is not present
Error from https://tx.fhir.org/r4: Error: A definition for CodeSystem 'http://fhir.de/CodeSystem/bfarm/ops' could not be found, so the value set cannot be expanded (from server, see log)
URL Mismatch https://gematik.de/fhir/isik//ValueSet/ProzedurenReanimationCodesOPS vs https://gematik.de/fhir/isik/ValueSet/ProzedurenReanimationCodesOPS
URL Mismatch https://gematik.de/fhir/isik//ValueSet/ProzedurenReanimationCodesSCT vs https://gematik.de/fhir/isik/ValueSet/ProzedurenReanimationCodesSCT
URL Mismatch https://gematik.de/fhir/isik//ValueSet/mii-vs-icu-body-site-observation-beatmung vs https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-body-site-observation-beatmung
URL Mismatch https://gematik.de/fhir/isik//ValueSet/mii-vs-icu-bodysite-observation-pupillenbefund vs https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-bodysite-observation-pupillenbefund
Wrong Display Name 'Künstliche Beatmung' for http://snomed.info/sct#40617009. Valid display is one of 8 choices: 'Artificial respiration' (en), 'Mechanical ventilation' (en), 'Artificial ventilation' (en), 'Mechanically assisted breathing' (en), 'Respiratory assist, mechanical' (en), 'Mechanically assisted ventilation' (en), 'Artificial respiration (procedure)' (en) or 'Artificial ventilation (regime/therapy)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
--
ValueSet.compose.include[0] (l1/c1996)
information
This SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Oxygen therapy (procedure)] and examples for no FSN: [Künstliche Beatmung])VALUESET_CONCEPT_DISPLAY_SCT_TAG_MIXED
URL Mismatch https://gematik.de/fhir/isik//ValueSet/mii-vs-icu-category-procedure-beatmung-snomed vs https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-category-procedure-beatmung-snomed
URL Mismatch https://gematik.de/fhir/isik//ValueSet/mii-vs-icu-code-observation-beatmung-loinc vs https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-code-observation-beatmung-loinc
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.36.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_DRAFT
0ms tx-op
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Validate "[urn:iso:std:iso:11073:10101#150656 ("Oxygenation Ratio")]"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Check "urn:iso:std:iso:11073:10101#150656"
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: CodeSystem found: urn:iso:std:iso:11073:10101|2024-12-05 for urn:iso:std:iso:11073:10101|2024-12-05
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: check code in (urn:iso:std:iso:11073:10101) at Coding
1ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Code "150656" found in urn:iso:std:iso:11073:10101|2024-12-05
Wrong whitespace in Display Name 'Total respiratory rate; total breath rate' for urn:iso:std:iso:11073:10101#152490. Valid display is 'MDC_VENT_RESP_BTSD_PSAZC_RATE' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Inspiratory time setting' for urn:iso:std:iso:11073:10101#16929632. Valid display is 'MDC_VENT_TIME_PD_INSP_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Tidal volume setting' for urn:iso:std:iso:11073:10101#16929196. Valid display is 'MDC_VENT_VOL_TIDAL_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'High pressure hold time setting Ventilator' for urn:iso:std:iso:11073:10101#16929860. Valid display is 'MDC_VENT_TIME_PD_INSP_THIGH_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Low pressure hold time setting Ventilator' for urn:iso:std:iso:11073:10101#16929864. Valid display is 'MDC_VENT_TIME_PD_EXP_TLOW_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Mean pressure Respiratory system airway --on ventilator' for urn:iso:std:iso:11073:10101#151975. Valid display is 'MDC_VENT_PRESS_AWAY_MEAN' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Pressure.max Respiratory system airway --on ventilator' for urn:iso:std:iso:11073:10101#151973. Valid display is 'MDC_VENT_PRESS_AWAY_MAX' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
URL Mismatch https://gematik.de/fhir/isik//ValueSet/mii-vs-icu-code-observation-beatmung-loinc-iso11073 vs https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-code-observation-beatmung-loinc-iso11073
URL Mismatch https://gematik.de/fhir/isik//ValueSet/mii-vs-icu-code-observation-beatmung-snomed vs https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-code-observation-beatmung-snomed
URL Mismatch https://gematik.de/fhir/isik//ValueSet/mii-vs-icu-code-observation-pupillengroesse vs https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-code-observation-pupillengroesse
URL Mismatch https://gematik.de/fhir/isik//ValueSet/mii-vs-icu-code-observation-pupillenlichtreaktion vs https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-code-observation-pupillenlichtreaktion
URL Mismatch https://gematik.de/fhir/isik//ValueSet/mii-vs-icu-code-observation-pupillensymmetrie vs https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-code-observation-pupillensymmetrie
URL Mismatch https://gematik.de/fhir/isik//ValueSet/mii-vs-icu-code-oservation-pupillenform-loinc vs https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-code-oservation-pupillenform-loinc
Wrong Display Name 'Künstliche Beatmung' for http://snomed.info/sct#40617009. Valid display is one of 8 choices: 'Artificial respiration' (en), 'Mechanical ventilation' (en), 'Artificial ventilation' (en), 'Mechanically assisted breathing' (en), 'Respiratory assist, mechanical' (en), 'Mechanically assisted ventilation' (en), 'Artificial respiration (procedure)' (en) or 'Artificial ventilation (regime/therapy)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
--
ValueSet.compose.include[0] (l1/c19586)
information
This SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Respiratory therapy (procedure), Respiratory assist, manual (procedure), Control of end expiratory pressure (procedure), Pulmonary resuscitation (procedure), Positive airway pressure therapy (regime/therapy)] and examples for no FSN: [Positive pressure ventilation, Mechanically assisted spontaneous ventilation, Non-invasive ventilation, Kontinuierliche positive Atemwegsdruckbeatmung, Dual pressure spontaneous ventilation support])VALUESET_CONCEPT_DISPLAY_SCT_TAG_MIXED
URL Mismatch https://gematik.de/fhir/isik//ValueSet/mii-vs-icu-code-procedure-beatmung-snomed vs https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-code-procedure-beatmung-snomed
The code 'LA33959-0' is not valid in the system http://loinc.org (Unknown code 'LA33959-0' in the CodeSystem 'http://loinc.org' version '2.82')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code 'LA33960-8' is not valid in the system http://loinc.org (Unknown code 'LA33960-8' in the CodeSystem 'http://loinc.org' version '2.82')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
Wrong Display Name 'Restless +1' for http://loinc.org#LA16474-1. Valid display is 'Restless' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
The code 'LA33962-4' is not valid in the system http://loinc.org (Unknown code 'LA33962-4' in the CodeSystem 'http://loinc.org' version '2.82')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code 'LA33963-2' is not valid in the system http://loinc.org (Unknown code 'LA33963-2' in the CodeSystem 'http://loinc.org' version '2.82')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code 'LA33964-0' is not valid in the system http://loinc.org (Unknown code 'LA33964-0' in the CodeSystem 'http://loinc.org' version '2.82')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code 'LA33965-7' is not valid in the system http://loinc.org (Unknown code 'LA33965-7' in the CodeSystem 'http://loinc.org' version '2.82')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code 'LA33966-5' is not valid in the system http://loinc.org (Unknown code 'LA33966-5' in the CodeSystem 'http://loinc.org' version '2.82')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code 'LA33967-3' is not valid in the system http://loinc.org (Unknown code 'LA33967-3' in the CodeSystem 'http://loinc.org' version '2.82')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
--
input/resources/ValueSet-mii-vs-icu-score-rass
error
URL Mismatch https://gematik.de/fhir/isik//ValueSet/mii-vs-icu-score-rass vs https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass
URL Mismatch https://gematik.de/fhir/isik//ValueSet/vs-mii-icu-bodysite-observation-monitoring-und-vitaldaten vs https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-bodysite-observation-monitoring-und-vitaldaten
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.36.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_DRAFT
0ms tx-op
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Validate "[urn:iso:std:iso:11073:10101#150017 ("Systolic blood pressure")]"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Check "urn:iso:std:iso:11073:10101#150017"
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: CodeSystem found: urn:iso:std:iso:11073:10101|2024-12-05 for urn:iso:std:iso:11073:10101|2024-12-05
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: check code in (urn:iso:std:iso:11073:10101) at Coding
0ms urn:iso:std:iso:11073:10101/vs|2024-12-05: Code "150017" found in urn:iso:std:iso:11073:10101|2024-12-05
Wrong Display Name 'Oxygen saturation in Arterial blood by Pulse oximetry' for urn:iso:std:iso:11073:10101#150456. Valid display is 'MDC_PULS_OXIM_SAT_O2' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Esophageal temperature' for urn:iso:std:iso:11073:10101#150372. Valid display is 'MDC_TEMP_ESOPH' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Nasopharynx temperature' for urn:iso:std:iso:11073:10101#150380. Valid display is 'MDC_TEMP_NASOPH' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Arterial oxygen saturation' for urn:iso:std:iso:11073:10101#150324. Valid display is 'MDC_SAT_O2_ART' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Ideal body weight (IBW)' for urn:iso:std:iso:11073:10101#188796. Valid display is 'MDC_MASS_BODY_EST_IBW' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Tympanic temperature' for urn:iso:std:iso:11073:10101#150392. Valid display is 'MDC_TEMP_TYMP' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Airway temperature' for urn:iso:std:iso:11073:10101#150356. Valid display is 'MDC_TEMP_AWAY' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
URL Mismatch https://gematik.de/fhir/isik//ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-iso11073 vs https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-iso11073
Wrong Display Name 'Sauerstoffsättigung in arteriellem Blut mittels Pulsoximetrie' for http://loinc.org#59408-5. Valid display is one of 3 choices: 'Oxygen saturation in Arterial blood by Pulse oximetry' (en-US), 'Oxygen saturation in Arterial blood by Pulse oximetry' (en-US) or 'SaO2 % BldA PulseOx' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Körpergewicht' for http://loinc.org#29463-7. Valid display is one of 3 choices: 'Body weight' (en-US), 'Body weight' (en-US) or 'Weight' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Körpergröße' for http://loinc.org#8302-2. Valid display is one of 3 choices: 'Body height' (en-US), 'Body height' (en-US) or 'Body height' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Körpergewicht [Perzentil] pro Alter' for http://loinc.org#8336-0. Valid display is one of 3 choices: 'Body weight [Percentile] Per age' (en-US), 'Body weight [Percentile] Per age' (en-US) or 'Bdy weight Prctl Per Age' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Körpertemperatur - Harnblase' for http://loinc.org#8334-5. Valid display is one of 3 choices: 'Body temperature - Urinary bladder' (en-US), 'Body temperature - Urinary bladder' (en-US) or 'Bdy temp Bladder' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Körpertemperatur - gemessen im Blut' for http://loinc.org#60834-9. Valid display is one of 3 choices: 'Blood temperature' (en-US), 'Blood temperature' (en-US) or 'Blood temp' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Körpertemperatur' for http://loinc.org#8310-5. Valid display is one of 3 choices: 'Body temperature' (en-US), 'Body temperature' (en-US) or 'Body temperature' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
URL Mismatch https://gematik.de/fhir/isik//ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-loinc vs https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-loinc
Wrong Display Name 'Herzfrequenz' for http://snomed.info/sct#364075005. Valid display is one of 3 choices: 'Heart rate' (en), 'Heart rate (observable entity)' (en) or 'Cardiac rate' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Körperkerntemperatur' for http://snomed.info/sct#276885007. Valid display is one of 2 choices: 'Core body temperature' (en) or 'Core body temperature (observable entity)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Körpergewicht' for http://snomed.info/sct#27113001. Valid display is one of 3 choices: 'Body weight' (en), 'Body weight, NOS' (en) or 'Body weight (observable entity)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Körpergröße' for http://snomed.info/sct#1153637007. Valid display is one of 2 choices: 'Body height (observable entity)' (en) or 'Body height' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Körperkerntemperatur gemessen am Trommelfell' for http://snomed.info/sct#415974002. Valid display is one of 5 choices: 'Tympanic temperature (observable entity)' (en), 'Tympanic temperature' (en), 'Aural temperature' (en), 'Core body temperature measured at tympanic membrane (observable entity)' (en) or 'Core body temperature measured at tympanic membrane' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Rektaltemperatur' for http://snomed.info/sct#307047009. Valid display is one of 4 choices: 'Rectal temperature' (en), 'Rectal temperature (observable entity)' (en), 'Core body temperature measured in rectum (observable entity)' (en) or 'Core body temperature measured in rectum' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Körperkerntemperatur gemessen im Ösophagus' for http://snomed.info/sct#431598003. Valid display is one of 6 choices: 'Temperature of esophagus (observable entity)' (en), 'Temperature of esophagus' (en), 'Temperature of oesophagus' (en), 'Core body temperature measured in esophagus (observable entity)' (en), 'Core body temperature measured in esophagus' (en) or 'Core body temperature measured in oesophagus' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Körperkerntemperatur gemessen im Nasopharynx' for http://snomed.info/sct#698831002. Valid display is one of 4 choices: 'Nasopharyngeal temperature' (en), 'Nasopharyngeal temperature (observable entity)' (en), 'Core body temperature measured in nasopharynx (observable entity)' (en) or 'Core body temperature measured in nasopharynx' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Körperkerntemperatur gemessen an der Harnblase' for http://snomed.info/sct#698832009. Valid display is one of 8 choices: 'Bladder temperature (observable entity)' (en), 'Bladder temperature' (en), 'Intravesical temperature' (en), 'Temperature of bladder' (en), 'Temperature of urinary bladder' (en), 'Core body temperature measured at urinary bladder (observable entity)' (en), 'Core body temperature measured at urinary bladder' (en) or 'Urinary bladder temperature' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Vaginaltemperatur' for http://snomed.info/sct#364246006. Valid display is one of 4 choices: 'Temperature of vagina' (en), 'Temperature of vagina (observable entity)' (en), 'Core body temperature measured vaginally (observable entity)' (en) or 'Core body temperature measured vaginally' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Orale Temperatur' for http://snomed.info/sct#415945006. Valid display is one of 6 choices: 'Oral temperature (observable entity)' (en), 'Oral temperature' (en), 'Core body temperature measured in sublingual space (observable entity)' (en), 'Core body temperature measured in sublingual space' (en), 'Estimated core body temperature measured in sublingual space (observable entity)' (en) or 'Estimated core body temperature measured in sublingual space' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Körperkerntemperatur im Blut gemessen' for http://snomed.info/sct#1222808002. Valid display is one of 3 choices: 'Temperature of blood' (en), 'Core body temperature measured in blood (observable entity)' (en) or 'Core body temperature measured in blood' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Stirntemperatur' for http://snomed.info/sct#415922000. Valid display is one of 4 choices: 'Forehead temperature (observable entity)' (en), 'Forehead temperature' (en), 'Temperature of forehead (observable entity)' (en) or 'Temperature of forehead' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
URL Mismatch https://gematik.de/fhir/isik//ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-snomed vs https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-snomed
Published code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not present
Published code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not present
Published code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not present
Published code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not present
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKLaboruntersuchung|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
This element does not match any known slice defined in the profile http://fhir.de/StructureDefinition/humanname-de-basis|1.5.4 (this may not be a problem, but you should check that it's not intended to match a slice)
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
This element does not match any known slice defined in the profile http://fhir.de/StructureDefinition/address-de-basis|1.5.4 (this may not be a problem, but you should check that it's not intended to match a slice)
This element does not match any known slice defined in the profile http://fhir.de/StructureDefinition/address-de-basis|1.5.4 (this may not be a problem, but you should check that it's not intended to match a slice)
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
This element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0-rc (this may not be a problem, but you should check that it's not intended to match a slice)
Wrong Display Name 'Inpatient' for http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP. Valid display is 'inpatient encounter' (en) (for the language(s) 'en-US')
Wrong Display Name 'Serologie' for http://loinc.org#18727-8. Valid display is one of 2 choices: 'Serology studies (set)' (en-US) or 'Serology studies (set)' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Methicillin-resistenter Staphylococcus aureus [Nachweis] in Probenmaterial mittels erregerspezifischer Kultur' for http://loinc.org#13317-3. Valid display is one of 3 choices: 'Methicillin resistant Staphylococcus aureus [Presence] in Specimen by Organism specific culture' (en-US), 'Methicillin resistant Staphylococcus aureus [Presence] in Specimen by Organism specific culture' (en-US) or 'MRSA Spec Ql Cult' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Positiv' for http://snomed.info/sct#10828004. Valid display is one of 6 choices: 'Positive' (en), 'Positive for' (en), 'Ruled in' (en), 'Presence of' (en), 'Present' (en) or 'Positive (qualifier value)' (en) (for the language(s) 'en-US')
Wrong Display Name 'Weiblich' for http://snomed.info/sct#248152002. Valid display is one of 2 choices: 'Female' (en) or 'Female (finding)' (en) (for the language(s) 'en-US')
Wrong Display Name 'Eye opening spontaneously' for http://loinc.org#LA6556-0. Valid display is 'Eyes open spontaneously' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Appendektomie' for http://snomed.info/sct#80146002. Valid display is one of 9 choices: 'Appendectomy' (en), 'Appendectomy, NOS' (en), 'Excision of appendix, NOS' (en), 'Primary appendectomy' (en), 'Appendicectomy, NOS' (en), 'Excision of appendix' (en), 'Appendicectomy' (en), 'Appendectomy (procedure)' (en) or 'Excision of appendix (procedure)' (en) (for the language(s) 'en-US')
Error in constraint 'mii-icu-1' with expression 'value.exists().not() implies dataAbsentReason.exists()': Error evaluating FHIRPath expression: The name 'value' is not valid for any of the possible types: [http://hl7.org/fhir/StructureDefinition/CodeableConcept] (@char 1)
ISiK-enc-8: The left side is inherently a collection, and so the expression 'coding.code != 'billing'' may fail or return false if there is more than one item in the content being evaluated
The canonical URL http://fhir.org/packages/de.basisprofil.r4/ImplementationGuide/de.basisprofil.r4 doesn't point to an actual ImplementationGuide resource
The ImplementationGuide is based on FHIR version 4.0.1 but package hl7.fhir.uv.subscriptions-backport.r4#1.1.0 is based on FHIR version 4.0.0. In general, this version mismatch should be avoided - some tools will try to make this work with variable degrees of success, but others will not even try
The ImplementationGuide uses package hl7.fhir.uv.ips#1.1.0 released on 2022-11-22, but the most recent appropriate version is 2.0.0. This reference is getting old and the more recent version should be considered
The ImplementationGuide uses package ihe.formatcode.fhir#1.4.0 released on 2025-05-20, but the most recent appropriate version is 1.5.0. This reference is getting old and the more recent version should be considered
The ImplementationGuide uses package hl7.fhir.uv.sdc#3.0.0 released on 2022-03-08, but the most recent appropriate version is 4.0.0. This reference is getting old and the more recent version should be considered
The extension http://hl7.org/fhir/StructureDefinition/regex|5.2.0 is deprecated with the note: 'This was deprecated in favor of using a constraint on the element using FHIRPath, since constraints allow for the provision of a human readable message associated with the regex'
Pinned the version of http://terminology.hl7.org/CodeSystem/v3-ActCode to 10.0.0 from choices of 10.0.0 (hl7.terminology.r4#7.1.0), 7.0.0 (hl7.terminology.r4#5.0.0), 9.0.0 (hl7.terminology.r4#6.3.0)
Conformance resource /__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/fsh-generated/resources/ImplementationGuide-Organspendeerkennung.json - the canonical URL (https://gematik.de/fhir/isik/ImplementationGuide/Organspendeerkennung) does not match the URL (https://gematik.de/fhir/isik//ImplementationGuide/Organspendeerkennung). Use the special-url parameter if you really mean for it not to match
Conformance resource /__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-PlannedEndDate.json - the canonical URL (https://gematik.de/fhir/isik/StructureDefinition/PlannedEndDate) does not match the URL (http://hl7.org/fhir/5.0/StructureDefinition/extension-Encounter.plannedEndDate). Use the special-url parameter if you really mean for it not to match
Conformance resource /__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-PlannedStartDate.json - the canonical URL (https://gematik.de/fhir/isik/StructureDefinition/PlannedStartDate) does not match the URL (http://hl7.org/fhir/5.0/StructureDefinition/extension-Encounter.plannedStartDate). Use the special-url parameter if you really mean for it not to match
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/conformance-expectation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '2.0.0', found versions: 0.3.0 (from hl7.terminology.r4#5.0.0), 1.0.0 (from hl7.terminology.r4#6.3.0), 2.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/conformance-expectation' to 'http://terminology.hl7.org/ValueSet/conformance-expectation|2.0.0'
There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/conformance-expectation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '2.0.0', found versions: 0.3.0 (from hl7.terminology.r4#5.0.0), 1.0.0 (from hl7.terminology.r4#6.3.0), 2.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/conformance-expectation' to 'http://terminology.hl7.org/ValueSet/conformance-expectation|2.0.0'
There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ActEncounterCode'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ActEncounterCode' to 'http://terminology.hl7.org/ValueSet/v3-ActEncounterCode|3.0.0'
There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ActPriority'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ActPriority' to 'http://terminology.hl7.org/ValueSet/v3-ActPriority|3.0.0'
There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v2-0092'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v2-0092' to 'http://terminology.hl7.org/ValueSet/v2-0092|3.0.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-name'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-name' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-name|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier' to 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/name-part-qualifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/name-part-qualifier' to 'http://hl7.org/fhir/ValueSet/name-part-qualifier|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-name'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-name' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-name|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier' to 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/data-absent-reason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/data-absent-reason' to 'http://hl7.org/fhir/StructureDefinition/data-absent-reason|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/data-absent-reason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/data-absent-reason' to 'http://hl7.org/fhir/StructureDefinition/data-absent-reason|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.2.0'
There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v2-0116'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v2-0116' to 'http://terminology.hl7.org/ValueSet/v2-0116|3.0.0'
There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType' to 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType|3.0.0'
A definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'
A definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'
A definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'
A definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'
A definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'
The code provided (http://snomed.info/sct#80146002) was not found in the value set 'ProzedurenCodesSCT' (https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT|6.0.0-rc), and a code from this value set is required: Wrong Display Name 'Appendektomie' for http://snomed.info/sct#80146002. Valid display is one of 9 choices: 'Appendectomy' (en), 'Appendectomy, NOS' (en), 'Excision of appendix, NOS' (en), 'Primary appendectomy' (en), 'Appendicectomy, NOS' (en), 'Excision of appendix' (en), 'Appendicectomy' (en), 'Appendectomy (procedure)' (en) or 'Excision of appendix (procedure)' (en) (for the language(s) 'en-US')
The code provided (http://snomed.info/sct#89666000) was not found in the value set 'ProzedurenReanimationCodesSCT' (https://gematik.de/fhir/isik/ValueSet/ProzedurenReanimationCodesSCT|6.0.0-rc), and a code from this value set is required: Wrong Display Name 'Kardiopulmonale Reanimation' for http://snomed.info/sct#89666000. Valid display is 'Cardiopulmonary resuscitation' (en-x-sctlang-90000000-00005090-07) (for the language(s) 'en-US')
The code provided (http://fhir.de/CodeSystem/bfarm/ops#8-771) was not found in the value set 'ProzedurenReanimationCodesOPS' (https://gematik.de/fhir/isik/ValueSet/ProzedurenReanimationCodesOPS|6.0.0-rc), and a code from this value set is required: Cannot invoke "String.length()" because "prefix" is null
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#AMB) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#AMB' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#AMB) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#AMB' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc')
The Coding provided (http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP) was not found in the value set 'ISiKEncounterClassDE' (https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc), and a code is required from this value set. (error message = The provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP: 'Inpatient'' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0-rc'; Wrong Display Name 'Inpatient' for http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP. Valid display is 'inpatient encounter' (en) (for the language(s) 'en-US'))
None of the codings provided are in the value set 'MII VS ICU Score RASS' (https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass|6.0.0-rc), and a coding from this value set is required) (codes = http://loinc.org#LA33966-5)
value should not start or finish with whitespace '\nDieses Profil ermöglicht die Abbildung von Besuchen/Aufenthalten eines Patienten in einer Gesundheitseinrichtung.\n\n**Motivation**\n\nInformationen über die Besuche des Patienten entlang seines \nBehandlungspfades im Krankenhaus sind ein wichtiger Bestandteil \ndes einrichtungsinternen Datenaustausches. \nSie ermöglichen die Unterscheidung von stationären und ambulanten \nsowie aufgenommenen und entlassenen Patienten. \nWeiterhin ist aus den Besuchsinformationen der aktuelle Aufenthaltsort \ndes Patienten (Fachabteilung, Station, Bettplatz) ermittelbar. \nKlinische Ressourcen werden in FHIR durch Verlinkung auf die \nEncounter-Ressource in einen Kontext zum Besuch gestellt. \nDieser Kontext ist wichtig für die Steuerung von Zugriffsberechtigungen \nund Abrechnungsprozessen. \n\nZu Beginn der meisten klinischen Workflows steht die Auswahl \ndes Besuchskontextes. \nDies geschieht bspw. durch das Suchen der Encounter-Ressource \nanhand von Eigenschaften wie Aufnahmenummer, Fallart oder Aufnahmedatum. \nDaraufhin werden die zutreffenden Suchergebnisse angezeigt \nund der gewünschte Besuch ausgewählt.\n\nIn FHIR werden Besuche, Aufenthalte, aber auch virtuelle Kontakte mit der `Encounter`-Ressource repräsentiert.\n\nWeitere Hinweise zu den Abgrenzungen der Begrifflichkeiten Fall und Kontakt finden sie unter [Fall-Begriff in ISiK](https://gemspec.gematik.de/ig/fhir/isik/basis/6.0.0-rc/Abbildung-des-Konstrukts-Fall.html).\n\n**Kompatibilität**\n\nFür das Profil ISiKKontaktGesundheitseinrichtung wird eine Kompatibilität \nmit folgenden Profilen angestrebt; \nallerdings kann nicht sichergestellt werden, dass Instanzen, \ndie gegen ISiKKontaktGesundheitseinrichtung valide sind, \nauch valide sind gegen:\n\n* Profil [Kontakt mit einer Gesundheitseinrichtung \nder Medizininformatik-Initiative](https://www.medizininformatik-initiative.de/fhir/core/modul-fall/StructureDefinition/KontaktGesundheitseinrichtung)\n\nHinweise zu Inkompatibilitäten können über die [Portalseite](https://service.gematik.de/servicedesk/customer/portal/16) gemeldet werden.'
value should not start or finish with whitespace ' Zulaessige Koerperstellen fuer lateralisierte Pupillenbefunde: linke oder rechte Pupille.\n\nDie Datenstruktur wurde dem laufenden Stand der Entwicklung des MII ICU Module entnommen - https://github.com/medizininformatik-initiative/kerndatensatzmodul-intensivmedizin/blob/master/input/fsh/valuesets/MII_VS_ICU_BodySite_Observation_Pupillenbefund.fsh - Details zur Kompatibilität mit dem ISiK Package der Stufe 6 wurden angepasst und Metadaten des Ursprungsschemas zum Teil entfernt. Stand 04.03.2026'
A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000274103/version/20251115' could not be found, so the code cannot be validated. Valid versions: http://snomed.info/sct/11000146104/version/20240930, http://snomed.info/sct/11000172109/version/20231115, http://snomed.info/sct/2011000195101/version/20230607, http://snomed.info/sct/32506021000036107/version/20230731, http://snomed.info/sct/45991000052106/version/20231130, http://snomed.info/sct/554471000005108/version/20250930, http://snomed.info/sct/731000124108/version/20230301, http://snomed.info/sct/731000124108/version/20240301, http://snomed.info/sct/731000124108/version/20250901, http://snomed.info/sct/827022005/version/20241216, http://snomed.info/sct/83821000000107/version/20230412, http://snomed.info/sct/900000000000207008/version/20240201, http://snomed.info/sct/900000000000207008/version/20250201 and http://snomed.info/xsct/900000000000207008/version/20250814
A definition for CodeSystem 'http://fhir.de/CodeSystem/bfarm/ops' version '2024' could not be found, so the code cannot be validated. No versions of this code system are known
Unknown code '726446007' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/900000000000207008/version/20250201' (International Edition)
When HL7 is publishing a resource, the owning committee must be stated using the http://hl7.org/fhir/StructureDefinition/structuredefinition-wg extension
When HL7 is publishing a resource, the owning committee must be stated using the http://hl7.org/fhir/StructureDefinition/structuredefinition-wg extension
Wrong Display Name 'BLOOD BANK STUDIES' for http://loinc.org#18717-9. Valid display is one of 2 choices: 'Blood bank studies (set)' (en-US) or 'Blood bank studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'CELL MARKER STUDIES' for http://loinc.org#18718-7. Valid display is one of 2 choices: 'Cell marker studies (set)' (en-US) or 'Cell marker studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'CHEMISTRY STUDIES' for http://loinc.org#18719-5. Valid display is one of 2 choices: 'Chemistry studies (set)' (en-US) or 'Chemistry studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'COAGULATION STUDIES' for http://loinc.org#18720-3. Valid display is one of 2 choices: 'Coagulation studies (set)' (en-US) or 'Coagulation studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'THERAPEUTIC DRUG MONITORING STUDIES' for http://loinc.org#18721-1. Valid display is one of 2 choices: 'Therapeutic drug monitoring studies (set)' (en-US) or 'Therapeutic drug monitoring studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'FERTILITY STUDIES' for http://loinc.org#18722-9. Valid display is one of 2 choices: 'Fertility studies (set)' (en-US) or 'Fertility studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'HEMATOLOGY STUDIES' for http://loinc.org#18723-7. Valid display is one of 2 choices: 'Hematology studies (set)' (en-US) or 'Hematology studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'SEROLOGY STUDIES' for http://loinc.org#18727-8. Valid display is one of 2 choices: 'Serology studies (set)' (en-US) or 'Serology studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'TOXICOLOGY STUDIES' for http://loinc.org#18728-6. Valid display is one of 2 choices: 'Toxicology studies (set)' (en-US) or 'Toxicology studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'URINALYSIS STUDIES' for http://loinc.org#18729-4. Valid display is one of 2 choices: 'Urinalysis studies (set)' (en-US) or 'Urinalysis studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'BLOOD GAS STUDIES' for http://loinc.org#18767-4. Valid display is one of 2 choices: 'Blood gas studies (set)' (en-US) or 'Blood gas studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'CELL COUNTS+DIFFERENTIAL STUDIES' for http://loinc.org#18768-2. Valid display is one of 2 choices: 'Cell counts+Differential studies (set)' (en-US) or 'Cell counts+Differential studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'LABORATORY STUDIES' for http://loinc.org#26436-6. Valid display is one of 2 choices: 'Laboratory studies (set)' (en-US) or 'Laboratory studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'CHEMISTRY CHALLENGE STUDIES' for http://loinc.org#26437-4. Valid display is one of 2 choices: 'Chemistry challenge studies (set)' (en-US) or 'Chemistry challenge studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'millimol per liter' for http://unitsofmeasure.org#mmol/L. Valid display is one of 2 choices: 'mmol/L' (en) or '(millimole) / (liter)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Administration of medicine' for http://snomed.info/sct#18629005. Valid display is one of 9 choices: 'Administration of medication' (en), 'Administration of medication, NOS' (en), 'Giving medication' (en), 'Administration of medication (procedure)' (en), 'Medication administration' (en), 'Medication administration treatments and procedures' (en), 'Medication treatment' (en), 'Administration of drug or medicament (procedure)' (en) or 'Administration of drug or medicament' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Künstliche Beatmung' for http://snomed.info/sct#40617009. Valid display is one of 8 choices: 'Artificial respiration' (en), 'Mechanical ventilation' (en), 'Artificial ventilation' (en), 'Mechanically assisted breathing' (en), 'Respiratory assist, mechanical' (en), 'Mechanically assisted ventilation' (en), 'Artificial respiration (procedure)' (en) or 'Artificial ventilation (regime/therapy)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong whitespace in Display Name 'Total respiratory rate; total breath rate' for urn:iso:std:iso:11073:10101#152490. Valid display is 'MDC_VENT_RESP_BTSD_PSAZC_RATE' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Inspiratory time setting' for urn:iso:std:iso:11073:10101#16929632. Valid display is 'MDC_VENT_TIME_PD_INSP_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Tidal volume setting' for urn:iso:std:iso:11073:10101#16929196. Valid display is 'MDC_VENT_VOL_TIDAL_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'High pressure hold time setting Ventilator' for urn:iso:std:iso:11073:10101#16929860. Valid display is 'MDC_VENT_TIME_PD_INSP_THIGH_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Low pressure hold time setting Ventilator' for urn:iso:std:iso:11073:10101#16929864. Valid display is 'MDC_VENT_TIME_PD_EXP_TLOW_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Mean pressure Respiratory system airway --on ventilator' for urn:iso:std:iso:11073:10101#151975. Valid display is 'MDC_VENT_PRESS_AWAY_MEAN' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Pressure.max Respiratory system airway --on ventilator' for urn:iso:std:iso:11073:10101#151973. Valid display is 'MDC_VENT_PRESS_AWAY_MAX' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Künstliche Beatmung' for http://snomed.info/sct#40617009. Valid display is one of 8 choices: 'Artificial respiration' (en), 'Mechanical ventilation' (en), 'Artificial ventilation' (en), 'Mechanically assisted breathing' (en), 'Respiratory assist, mechanical' (en), 'Mechanically assisted ventilation' (en), 'Artificial respiration (procedure)' (en) or 'Artificial ventilation (regime/therapy)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Restless +1' for http://loinc.org#LA16474-1. Valid display is 'Restless' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Oxygen saturation in Arterial blood by Pulse oximetry' for urn:iso:std:iso:11073:10101#150456. Valid display is 'MDC_PULS_OXIM_SAT_O2' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Esophageal temperature' for urn:iso:std:iso:11073:10101#150372. Valid display is 'MDC_TEMP_ESOPH' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Nasopharynx temperature' for urn:iso:std:iso:11073:10101#150380. Valid display is 'MDC_TEMP_NASOPH' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Arterial oxygen saturation' for urn:iso:std:iso:11073:10101#150324. Valid display is 'MDC_SAT_O2_ART' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Ideal body weight (IBW)' for urn:iso:std:iso:11073:10101#188796. Valid display is 'MDC_MASS_BODY_EST_IBW' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Tympanic temperature' for urn:iso:std:iso:11073:10101#150392. Valid display is 'MDC_TEMP_TYMP' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Airway temperature' for urn:iso:std:iso:11073:10101#150356. Valid display is 'MDC_TEMP_AWAY' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Sauerstoffsättigung in arteriellem Blut mittels Pulsoximetrie' for http://loinc.org#59408-5. Valid display is one of 3 choices: 'Oxygen saturation in Arterial blood by Pulse oximetry' (en-US), 'Oxygen saturation in Arterial blood by Pulse oximetry' (en-US) or 'SaO2 % BldA PulseOx' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Körpergewicht' for http://loinc.org#29463-7. Valid display is one of 3 choices: 'Body weight' (en-US), 'Body weight' (en-US) or 'Weight' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Körpergröße' for http://loinc.org#8302-2. Valid display is one of 3 choices: 'Body height' (en-US), 'Body height' (en-US) or 'Body height' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Körpergewicht [Perzentil] pro Alter' for http://loinc.org#8336-0. Valid display is one of 3 choices: 'Body weight [Percentile] Per age' (en-US), 'Body weight [Percentile] Per age' (en-US) or 'Bdy weight Prctl Per Age' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Körpertemperatur - Harnblase' for http://loinc.org#8334-5. Valid display is one of 3 choices: 'Body temperature - Urinary bladder' (en-US), 'Body temperature - Urinary bladder' (en-US) or 'Bdy temp Bladder' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Körpertemperatur - gemessen im Blut' for http://loinc.org#60834-9. Valid display is one of 3 choices: 'Blood temperature' (en-US), 'Blood temperature' (en-US) or 'Blood temp' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Körpertemperatur' for http://loinc.org#8310-5. Valid display is one of 3 choices: 'Body temperature' (en-US), 'Body temperature' (en-US) or 'Body temperature' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Herzfrequenz' for http://snomed.info/sct#364075005. Valid display is one of 3 choices: 'Heart rate' (en), 'Heart rate (observable entity)' (en) or 'Cardiac rate' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Körperkerntemperatur' for http://snomed.info/sct#276885007. Valid display is one of 2 choices: 'Core body temperature' (en) or 'Core body temperature (observable entity)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Körpergewicht' for http://snomed.info/sct#27113001. Valid display is one of 3 choices: 'Body weight' (en), 'Body weight, NOS' (en) or 'Body weight (observable entity)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Körpergröße' for http://snomed.info/sct#1153637007. Valid display is one of 2 choices: 'Body height (observable entity)' (en) or 'Body height' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Körperkerntemperatur gemessen am Trommelfell' for http://snomed.info/sct#415974002. Valid display is one of 5 choices: 'Tympanic temperature (observable entity)' (en), 'Tympanic temperature' (en), 'Aural temperature' (en), 'Core body temperature measured at tympanic membrane (observable entity)' (en) or 'Core body temperature measured at tympanic membrane' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Rektaltemperatur' for http://snomed.info/sct#307047009. Valid display is one of 4 choices: 'Rectal temperature' (en), 'Rectal temperature (observable entity)' (en), 'Core body temperature measured in rectum (observable entity)' (en) or 'Core body temperature measured in rectum' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Körperkerntemperatur gemessen im Ösophagus' for http://snomed.info/sct#431598003. Valid display is one of 6 choices: 'Temperature of esophagus (observable entity)' (en), 'Temperature of esophagus' (en), 'Temperature of oesophagus' (en), 'Core body temperature measured in esophagus (observable entity)' (en), 'Core body temperature measured in esophagus' (en) or 'Core body temperature measured in oesophagus' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Körperkerntemperatur gemessen im Nasopharynx' for http://snomed.info/sct#698831002. Valid display is one of 4 choices: 'Nasopharyngeal temperature' (en), 'Nasopharyngeal temperature (observable entity)' (en), 'Core body temperature measured in nasopharynx (observable entity)' (en) or 'Core body temperature measured in nasopharynx' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Körperkerntemperatur gemessen an der Harnblase' for http://snomed.info/sct#698832009. Valid display is one of 8 choices: 'Bladder temperature (observable entity)' (en), 'Bladder temperature' (en), 'Intravesical temperature' (en), 'Temperature of bladder' (en), 'Temperature of urinary bladder' (en), 'Core body temperature measured at urinary bladder (observable entity)' (en), 'Core body temperature measured at urinary bladder' (en) or 'Urinary bladder temperature' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Vaginaltemperatur' for http://snomed.info/sct#364246006. Valid display is one of 4 choices: 'Temperature of vagina' (en), 'Temperature of vagina (observable entity)' (en), 'Core body temperature measured vaginally (observable entity)' (en) or 'Core body temperature measured vaginally' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Orale Temperatur' for http://snomed.info/sct#415945006. Valid display is one of 6 choices: 'Oral temperature (observable entity)' (en), 'Oral temperature' (en), 'Core body temperature measured in sublingual space (observable entity)' (en), 'Core body temperature measured in sublingual space' (en), 'Estimated core body temperature measured in sublingual space (observable entity)' (en) or 'Estimated core body temperature measured in sublingual space' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Körperkerntemperatur im Blut gemessen' for http://snomed.info/sct#1222808002. Valid display is one of 3 choices: 'Temperature of blood' (en), 'Core body temperature measured in blood (observable entity)' (en) or 'Core body temperature measured in blood' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Stirntemperatur' for http://snomed.info/sct#415922000. Valid display is one of 4 choices: 'Forehead temperature (observable entity)' (en), 'Forehead temperature' (en), 'Temperature of forehead (observable entity)' (en) or 'Temperature of forehead' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
This SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Oxygen therapy (procedure)] and examples for no FSN: [Künstliche Beatmung])
This SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Respiratory therapy (procedure), Respiratory assist, manual (procedure), Control of end expiratory pressure (procedure), Pulmonary resuscitation (procedure), Positive airway pressure therapy (regime/therapy)] and examples for no FSN: [Positive pressure ventilation, Mechanically assisted spontaneous ventilation, Non-invasive ventilation, Kontinuierliche positive Atemwegsdruckbeatmung, Dual pressure spontaneous ventilation support])
The code '8-772' is not valid in the system http://fhir.de/CodeSystem/bfarm/ops (A definition for CodeSystem 'http://fhir.de/CodeSystem/bfarm/ops' could not be found, so the code cannot be validated)
The code '8-779' is not valid in the system http://fhir.de/CodeSystem/bfarm/ops (A definition for CodeSystem 'http://fhir.de/CodeSystem/bfarm/ops' could not be found, so the code cannot be validated)